I/O Settings
91
ZG User’s Manual
3
FUNCTION SETTINGS
Setting Scaling
With analog output, the relationship between the displayed measured value and output
value can be freely set as the measurement value is converted to a current of 4 to 20 mA
or a voltage of -10 to +10 V, and is then output. Match the settings to suit the connected
external device.
Enter the output values for any two current values or voltage values to set the output
range. (default value: OFF)
Example: Set 0 mm to 4 mA, and 5 mm to 20 mA. (for current output)
5
4
0
20
0
5
4
0
20
-
5
-
5
Output current
(mA)
Measurement
value
(mm)
Output current
(mA)
Measurement
value
(mm)