Measurement Settings
86
ZG User’s Manual
Slope Correction
Registering the reference position
Register the reference position.
FUN mode-[MEAS]-[CORECT]-[SLOPE]-[REF.POINT]
1
Set the measurement target in
place, and press the SET key.
2
Specify the start and end lines for
point 1.
Left/Right key: Moves the cursor.
SET: Applies the setting.
ESC key: Cancels the setting.
3
Select the measurement point to
be used as the reference.
Select which position (average, peak
or bottom) within the specified region
is to be taken as the measurement
point.
4
Specify the start and end lines for
point 2.
Left/Right key: Moves the cursor.
SET: Applies the setting.
ESC key: Cancels the setting.
POINT1 START
[ 0]LINE SET
MEAS/REF.POINT
POINT1 START
[128]LINE SET
MEAS/REF.POINT
1AVE 2PEAK
3BTM
MEAS/REF.POINT
POINT1
SELECT
POINT2 START
[128]LINE SET
MEAS/REF.POINT