3-78
3-5 Parameter Unit Specifications
3
Specifications
3-5 Parameter Unit Specifications
R88A-PR02G Hand-held Parameter Unit
The Parameter Unit is required to operate the Servo Drive from a distance away from the Servo
Drive, or to operate and monitor the Servo Drive from a control panel.
The cable connected to the Parameter Unit is 1.5 m long.
General Specifications
Performance Specifications
Item
Specifications
Ambient operating
temperature and humidity
0 to 55
°
C, 90% RH max. (with no condensation)
Ambient storage
temperature and humidity
−
20 to 80
°
C, 90% RH max. (with no condensation)
Operating and storage
atmosphere
No corrosive gases
Vibration resistance
5.9 m/s
2
max.
Item
Specifications
Type
Hand-held
Cable length
1.5 m
Connectors
Mini DIN 8-pin MD connector
Display
Seven-segment LED display
Outer diameter
62 (W)
×
114 (H)
×
15 (D) mm
Weight
Approx. 0.1 kg (including cable)
Communi
ca
ti
ons specificatio
ns
Standard
RS-232
Communications method Asynchronous (ASYNC)
Baud rate
9,600 bps
Start bits
1 bit
Data
8 bits
Parity
No
Stop bits
1 bit