![Omron OMNUC G Скачать руководство пользователя страница 266](http://html.mh-extra.com/html/omron/omnuc-g/omnuc-g_user-manual_742936266.webp)
5-33
5-16 Gain Switching
Ope
rati
n
g Func
tions
5
Timings for Gain Switch Setting (Pn031)
Switching between gain 1 and gain 2 will be performed as illustrated below.
Note that Position Loop Gain will be switched according to the setting for Pn035.
Gain Switch Setting (Pn031) = 2: Switching from Network
Gain switches instantly when commanded from the network.
Gain Switch Setting (Pn031) = 3: Switching by an amount of change in torque
command
The torque command change amount (angular acceleration and deceleration speed command) is
set in units of 0.05%/166
μ
s.
Gain Switch is canceled if the change amount vibrates and fails to meet the switching time.
The change amount is approximately 6 units when switching 4% in 2 ms. (0.33% change in
166
μ
s)
Gain 1
Gain 1
Gain 2
Gain switch command
Position command
1
1
2
2
2
2
Pn032
Pn032
Pn034
Pn034
Pn033
Pn033
Pn034
Pn034
Pn032
Pn032
Speed command
Torque command
Amount of change
in torque
Gain 1
Gain 1
Gain 1