9-10
9-1 Parameter Tables
Appe
ndix
9
040
Reserved
Do not change.
0
---
---
---
041
Emergency Stop
Input
Setting
Enables the Emergency Stop Input (STOP).
1
---
0 to 1
C
0
Disabled
1
Enabled (alarm code 87 issued on OPEN)
042
Origin Proximity
Input Logic
Setting
Sets the logic for the Origin Proximity Input (DEC).
1
---
0 to 1
C
0
N.C contact (origin proximity detected on
OPEN)
1
N.O contact (origin proximity detected on
CLOSE)
043
Operating
Direction Setting
Sets the relationship between polarity of operation
data sent over the network and the direction of
Servomotor rotation.
1
---
0 to 1
C
0
Sets the reverse direction as the positive
direction (+).
1
Sets the forward direction as the positive
direction (+).
044
Input Signal
Selection
Sets the terminal assignment for Drive Prohibit
Input.
0
---
0 to 1
C
0
Sets CN1 pin 19 to POT, CN1 pin 20 to
NOT.
1
Sets CN1 pin 19 to NOT, CN1 pin 20 to
POT.
045
Reserved
Do not change.
0
---
---
---
046
Reserved
Do not change.
0
---
---
---
047
Reserved
Do not change.
0
---
---
---
048
Reserved
Do not change.
0
---
---
---
049
Reserved
Do not change.
0
---
---
---
04A
Reserved
Do not change.
0
---
---
---
04B
Reserved
Do not change.
0
---
---
---
04C
Reserved
Do not change.
0
---
---
---
04D
Reserved
Do not change.
0
---
---
---
04E
Reserved
Do not change.
0
---
---
---
04F
Reserved
Do not change.
0
---
---
---
050
Reserved
Do not change.
0
---
---
---
051
Reserved
Do not change.
0
---
---
---
052
Reserved
Do not change.
0
---
---
---
053
Speed Limit
Sets the speed limit for torque control mode.
(The value is an absolute value)
This parameter is limited by the Overspeed
Detection Level Setting (Pn073).
50
r/min
−
20000 to
20000
B
054
Reserved
Do not change.
0
---
---
---
055
Reserved
Do not change.
0
---
---
---
056
Reserved
Do not change.
0
---
---
---
057
Reserved
Do not change.
0
---
---
---
058
Soft Start
Acceleration
Time
Sets the acceleration time for speed control mode.
Acceleration time [s] from 0 r/min to maximum
speed [r/min] = Set value
×
2 ms
0
×
2 ms 0 to 5000
B
059
Soft Start
Deceleration
Time
Sets the deceleration time for speed control mode.
Deceleration time [s] from maximum speed [r/min]
to 0 r/min = Set value
×
2 ms
0
×
2 ms 0 to 5000
B
05A
Reserved
Do not change.
0
---
---
---
Pn
No.
Parameter name Setting
Explanation
Default
Setting
Unit
Setting
Range
Attribute
Set
value