![Omron OMNUC G Скачать руководство пользователя страница 193](http://html.mh-extra.com/html/omron/omnuc-g/omnuc-g_user-manual_742936193.webp)
4-12
4-2 Wiring
System Design
4
Selecting Connecting Cables
Encoder Cables (Standard Cables)
Select an Encoder Cable matching the Servomotor to be used.
Servomotor type
Encoder Cable
Comments
3
,
000-r/min Servomotors
50 to 750 W
R88A-CRGA
@@@
C
The
@@@
digits in the model
number indicate the cable
length(3 m, 5 m, 10 m, 15 m,
20 m, 30 m, 40 m, or 50 m).
Example model number for a
3-m cable:
R88A-CRGA003C
50 to 750 W
R88A-CRGB
@@@
C
1 to 5 kW
R88A-CRGC
@@@
N
3,000-r/min Flat Servomotors
100 to 400 W
R88A-CRGA
@@@
C
100 to 400 W
R88A-CRGB
@@@
C
2,000-r/min Servomotors
(1
,
500-r/min Servomotors)
1 to 7.5 kW
R88A-CRGC
@@@
N
1,000-r/min Servomotors
900 W to 6 kW
R88A-CRGC
@@@
N
ABS
INC
ABS
INC