![Omron OMNUC G Скачать руководство пользователя страница 334](http://html.mh-extra.com/html/omron/omnuc-g/omnuc-g_user-manual_742936334.webp)
6-3
6-2 Preparing for Operation
Opera
tion
6
Servo Drive Display and Settings
The display for the Servo Driver R88D-GN
@
is illustrated below.
The display shows the node address setting for MECHATROLINK-II, alarm display for the Servo
Drive, and the communications status.
Note 1. The node address is only loaded once when the control power supply is turned ON.
Changes made after turning the power ON will not be applied until the power is turned ON
next time.
Do not change the rotary switch setting after turning the power ON.
Note 2. The setting range for the node address setting rotary switch is 1 to 31.
The actual node address used on the network will be the sum of the rotary switch setting
and the offset value of 40h.
If the rotary switch setting is not between 1 and 31, a node address setting error (alarm code
82) will occur.
Rotary Switch Set Value
Description
1 to 31
Node address = Set value + 40h
(41h
≤
Node address
≤
5Fh)
Others
Alarm code 82 occurs.
MECHATROLINK-II
communications
status LED
indicator (COM)
7-segment LED (2 digits)
Analog monitor pins
Speed monitor
Torque monitor
Signal ground
SP:
IM:
G:
Rotary switches for
setting a node
address
G
IM
SP
COM
X10
3
2
1
0
ADR
AC SERVO DRIVER
X1
6
7
8
9 0 1 2
3
4
5