3-14
3-1 Servo Drive Specifications
3
Specifications
Control Input Circuits
Control Inputs
For the relay contact, use either a switch, or a transistor with an open-collector output.
Control Output Circuits
Control Outputs
1
+24VIN
4.7
Ω
Signal Levels
ON level: 10 V min.
OFF level: 3 V max.
External power supply:
12 VDC
±
5% to
24 VDC
±
5%
Power supply capacity:
50 mA min. (per Unit)
Photocoupler input
To other input circuit ground commons
To other input circuits
Servo Drive
+
−
−
X
Di
To other output
circuits
X
Di
+
External power supply
24 VDC
±
1 V
Maximum operating voltage: 30 VDC
Maximum output current: 50 mA
Di: Diode for preventing surge voltage