6-23
6-4 Setting the Mode
Opera
tion
6
Parameter Write Mode
Settings changed in the Parameter Setting Mode must be saved to the EEPROM. To do so, the
following procedure must be performed.
1. Saving Changed Settings
2. Returning to Parameter Write Mode
Key
operation
Display example
Explanation
Press the
key to display Parameter Write Mode.
Press the
key to switch to Parameter Write Mode.
Press the
key for 5 s or longer.
The bar indicator will increase.
Writing will start. (This display will appear only momentarily.)
This display indicates a normal completion. In addition to the
,
either
or
may be displayed. If
is displayed,
writing has been completed normally, but some of the changed parameters
will be enabled only after the power has been turned OFF and ON again.
Turn OFF the Servo Drive power supply and then turn it ON again.
is displayed if there is a writing error. Write the data again.
Key
operation
Display example
Explanation
Press the
key to return to the Parameter Write Mode Display.
If a write error occurs, write the data again. If write errors continue to occur,
there may be a fault in the Servo Drive.
Do not turn OFF the power supply while writing to EEPROM. Incorrect data
may be written if the power supply is turned OFF. If the power supply is
turned OFF, perform the settings again for all parameters, and write the
data again.
Do not disconnect the Parameter Unit from the Servo Drive during the time
from writing start (
) to writing completion (
or
). If the Parameter Unit is disconnected, repeat the procedure
from the beginning.
Precautions