User Parameters
10
-
13
* 1. Not initialized. (PV-E specifications: A1-00 = 0)
* 2. For Inverters with a capacity of 55 kW or more: 2.00
* 3. Setting range and initial setting depend on Inverter capacity.
* 4. Setting for 200 V class Inverters. For 400 V class Inverters, double the value.
* 5. Factory setting in the parentheses is for 3-wire sequence.
* 6. The contents is ignored if the setting is 0.0.
L1-02
Motor protection time
1.0
L1-03
Alarm operation selection during motor overheating
3
L1-04
Motor overheating operation selection
1
L1-05
Motor temperature input filter time
0.20
L2-01
Momentary power loss detection
0
L2-02
Momentary power loss ridethru time
0.1
*3
L2-03
Min. baseblock time
0.1
L2-04
Voltage recovery time
0.3
L2-05
Undervoltage detection level
190
*4
L3-01
Stall prevention selection during accel
1
L3-02
Stall prevention level during accel
120
L3-04
Stall prevention selection during decel
1
L3-05
Stall prevention selection during running
1
L3-06
Stall prevention level during running
120
L4-01
Speed agreement detection level
0.0
L4-02
Speed agreement detection width
2.0
L4-05
Operation when frequency reference is missing
0
L4-06
Frequency Reference for loss of Frequency Reference
80%
L5-01
Number of auto restart attempts
0
L5-02
Auto restart operation selection
0
L6-01
Torque detection selection 1
0
L6-02
Torque detection level 1
150
L6-03
Torque detection time 1
0.1
L8-02
Overheat pre-alarm level
95
L8-03
Operation selection after overheat pre-alarm
3
L8-09
Ground protection selection
1
L8-11
Cooling fan control delay time
60
L8-12
Ambient temperature
45
L8-15
OL2 characteristics selection at low speeds
1
L8-18
Soft CLA selection
1
N1-01
Hunting-prevention function selection
1
N1-02
Hunting-prevention gain
1.00
N3-01
High-slip braking deceleration frequency width
5
N3-02
High-slip braking current limit
150
N3-03
High-slip braking stop dwell time
1.0
N3-04
High-slip braking OL time
40
o1-01
Monitor selection
6
o1-02
Monitor selection after power up
1
o1-03
Frequency units of reference setting and monitor
0
o1-05
LCD Brightness
3
o2-01
LOCAL/REMOTE key enable/disable
1
o2-02
STOP key during control circuit terminal operation
1
o2-03
Parameter initial value
0
o2-04
kVA selection
0
*3
o2-05
Frequency reference setting method selection
0
o2-06
Operation selection when digital operator is disconnected
0
o2-07
Cumulative operation time setting
0
o2-08
Cumulative operation time selection
0
o2-09
Initialize mode
5
o2-10
Fan operation time setting
0
o2-12
Fault trace history initialisation
0
o3-01
Copy function selection
0
o3-02
Read permitted selection
0
Table 10.1 Parameters (Continued)
No.
Name
Factory
Setting
Setting