8
Appendixes
FZ3 User's Manual
FAQ
261
●
Is test measurement being performed?
Data cannot be output to external devices during test measurement.
About Serial Interface (RS-232C/422 Connection)
No communication available
●
Are the cables connected correctly?
●
Are the communication specifications of the external devices compatible with the controller?
You can check the communication status in the Confirmation window.
Reference:
Checking Communication Status (Non-procedure) (p.149)
The controller works fine initially, but there is not response after a while
●
Is the buffer memory of the PC full?
Please verify if data can be received correctly based on current settings.
Data cannot be saved
●
Are the communication specifications of the external devices compatible with the controller?
●
Is "Flow control" in communication specifications set to "None"?
To save data, set "Flow control" to "None".
Reference:
Setting Communication Specifications (RS-232C/422-PLC Link) (p.126)
Setting Communication Specifications (RS-232C/422 - Non-procedure) (p.147)