Controlling/Outputting through Parallel Communication
FZ3 User's Manual
Example) When 1 expressions are set in [Parallel Data Output]:
Note
●
The output signal functions the same as when "Output Control" is set to "None".
When "Output Control" Is Set to "None" (p.184)
Input signal
Signal
Function
DI0 to 6
OFF
DI7
This is the execution trigger.
After DI0 to 6 is set, turn DI7 ON after an interval over 1 ms.
Note
●
The ERROR signal turns on when the input command is not correctly performed.
When "Output Control" Is Set to "Handshaking"
The controller outputs measurement results while synchronized with external devices. If this function is
used when multiple measurement results are output in sequence, it enables efficient and effective data
transfer.