5
Changing
the
System
Environment
FZ3 User's Manual
Setting the System Operation Environment
117
1.
On the Main screen, tap the [System] menu - [Controller] - [STEP setting].
2.
Set the filter width in the "STEP setting" area.
Setting item
Set value
[Factory default]
Description
STEP signal filter width [μs]
●
[100]
●
200
●
300
●
400
●
500
Sets the filter width.
Setting the RUN Window Password [Password Setting]
Operation on the RUN window can be locked with a password.
The following 3 operations can be locked.
●
Switching from the RUN window to the ADJUST window
●
Performing simplified non-stop adjustment on the RUN window
●
Changing screen structure of the RUN window
1.
On the Main screen, tap the [System] menu - [Controller] - [Password setting].
The Password Setting window is displayed.