Controlling/Outputting through Parallel Communication
FZ3 User's Manual
Checking Communication Status (Parallel Interface)
Check the communication status with the external devices connected with a parallel interface. You can
check whether wiring and communication settings have been performed correctly.
1.
On the Main screen, tap [System] - [Communication] - [Parallel].
The Parallel window is displayed.
2.
Tap [Confirmation] to check the I/O status.
ON
Description
STEP0,
STEP1
The input status of each signal from the external device to the controller is displayed.
When a signal is input, the background color becomes red.
DSA0, DSA1
DI
RUN
The output status of each signal is displayed.
When a signal is output, the background color becomes red.
The output status from each signal of the controller to external devices can be
specified.
Changes between ON and OFF and between 0 and 1 can be simulated without
performing measurement.
GATE0,
GATE1
BUSY
OR0, OR1
ERR
READY0,
READY1
DO
Important
●
That status of each of the parallel terminal signals STEP, DSA, GATE, OR, and READY can be checked
on the screen with STEP0, DSA0, GATE0, OR0, and READY0.
Acesst 1.0 6251194
Содержание FZ3 Series
Страница 10: ...1 Before Operation 8 Operation Flow FZ3 User s Manual Operation Flow Operation flow is explained here...
Страница 28: ...1 Before Operation 26 Saving Settings and Turning Power Off FZ3 User s Manual...
Страница 60: ...2 Setting Scenes Measurement Flow 58 Editing Scene Groups FZ3 User s Manual...
Страница 106: ...4 Saving Loading Data 104 Loading Settings Data to Controller FZ3 User s Manual...
Страница 122: ...5 Changing the System Environment 120 Setting the System Operation Environment FZ3 User s Manual...