128
Communicating through Serial Communication (PLC Link)
FZ3 User's Manual
Timeout [s]
1 to 120
[5]
Set the time in which a timeout error will occur in
seconds.
[Note 1]: If a speed of [38400 bps] or higher is selected, effective communication cannot be
guaranteed depending on the cable length because speeds of over 20 kbps are not defined in
RS-232C standards.In these cases, set the communication speed at [19200 bps] or lower.
3.
Tap [PLC Link].
The PLC Link Setting window is displayed.
4.
Set the following items.
Setting item
Set value
[Factory default]
Description
Command area
Area
●
[CIO Area(CIO)]
●
Work Area(WR)
●
Holding Bit Area(HR)
●
Auxiliary Bit Area(AR)
●
DM Area (DM)
●
EM Area(EMO)
Set the communication
area.
Address
0 to 99999
[0]
Set the communication
address.
Response area
Area
●
[CIO Area(CIO)]
●
Work Area(WR)
●
Holding Bit Area(HR)
●
Auxiliary Bit Area(AR)
●
DM Area (DM)
●
EM Area(EMO)
Set the communication
area.
Acesst 1.0 6251194
Содержание FZ3 Series
Страница 10: ...1 Before Operation 8 Operation Flow FZ3 User s Manual Operation Flow Operation flow is explained here...
Страница 28: ...1 Before Operation 26 Saving Settings and Turning Power Off FZ3 User s Manual...
Страница 60: ...2 Setting Scenes Measurement Flow 58 Editing Scene Groups FZ3 User s Manual...
Страница 106: ...4 Saving Loading Data 104 Loading Settings Data to Controller FZ3 User s Manual...
Страница 122: ...5 Changing the System Environment 120 Setting the System Operation Environment FZ3 User s Manual...