FZ3 User's Manual
Controlling/Outputting through Parallel Communication
189
Note
●
The output signal functions the same as when "Output Control" is set to "None".
When "Output Control" Is Set to "None" (p.184)
Scene/Scene Group Switch
Output signal
Signal
Function
RUN
Turns on when the controller is available for measurement and the RUN window is displayed. Turns
off in the ADJUST window.
BUSY
Indicates that the controller is currently switching the scene or scene group. Do not input next
command while the BUSY signal is ON. Otherwise, on-going processing or commands that are
input will not be performed correctly.