Controlling/Outputting through Parallel Communication
FZ3 User's Manual
Input signal Scene switching
Signal
Function
DI0 to 4
Set Scene No. (0 to 31).
DI5
ON
DI6
OFF
DI7
This is the execution trigger.
After DI0 to 6 is set, turn DI7 ON after an interval over 1 ms.
BUSY signal is ON during execution of commands. After checking that the BUSY signal has turned
on, turn DI7 OFF, and then turn DI0 to 6 OFF.
Input signal Scene group switching
Signal
Function
DI0 to 4
Sets the scene group No. (0 to 31).
DI5
ON
DI6
ON
DI7
This is the execution trigger.
After DI0 to 6 is set, turn DI7 ON after an interval over 1 ms.
BUSY signal is ON during execution of commands. After checking that the BUSY signal has turned
on, turn DI7 OFF, and then turn DI0 to 6 OFF.
About Multi-input Function
The function that enables continuous high speed image input is called the multiple image input
function.The next STEP signal can be received at the point when image input is complete. It is not
necessary to wait until measurement processing is complete. Whether image input is complete or not
can be checked with the status of the READY signal. Even if the READY signal is on when
measurement processing is being executed, the next STEP signal can be received. If STEP is input
while READY is OFF, the ERROR terminal turns on.
Acesst 1.0 6251194
Содержание FZ3 Series
Страница 10: ...1 Before Operation 8 Operation Flow FZ3 User s Manual Operation Flow Operation flow is explained here...
Страница 28: ...1 Before Operation 26 Saving Settings and Turning Power Off FZ3 User s Manual...
Страница 60: ...2 Setting Scenes Measurement Flow 58 Editing Scene Groups FZ3 User s Manual...
Страница 106: ...4 Saving Loading Data 104 Loading Settings Data to Controller FZ3 User s Manual...
Страница 122: ...5 Changing the System Environment 120 Setting the System Operation Environment FZ3 User s Manual...