6
M
eth
od
s
fo
rC
on
ne
ctin
g
an
d
C
om
m
un
ica
tin
g
w
ith
E
xte
rn
al
D
ev
ice
s
FZ3 User's Manual
Communicating through Serial Communication (PLC Link)
133
Command (PLC to Controller)
Command area
top channel
Command
code
Bit
Description
15-12
11-8
7-4
3-0
+2
1030
0001
0000
0011
0000
Set command
codes.
+3
0010
0000
0000
0001
0000
Response (Controller to PLC)
Response
area
top channel
Bit
Description
15-12
11-8
7-4
3-0
+2
0001
0000
0011
0000
Command code
Store response target command codes.
+3
0000
0000
0001
0000
+4
0000
0000
0000
0000
Response code
Command execution result
OK: 0 (0000 0000)
NG: -1 (FFFF FFFF)
+5
0000
0000
0000
0000
Clearing Measurement Values
Clears all measurement values.
Command (PLC to Controller)
Command area
top channel
Command
code
Bit
Description
15-12
11-8
7-4
3-0
+2
2010
0010
0000
0001
0000
Set command
codes.
+3
0010
0000
0000
0001
0000
Response (Controller to PLC)
Response
area
top channel
Bit
Description
15-12
11-8
7-4
3-0
+2
0010
0000
0001
0000
Command code
Store response target command codes.
+3
0000
0000
0001
0000
+4
0000
0000
0000
0000
Response code
Command execution result
OK: 0 (0000 0000)
NG: -1 (FFFF FFFF)
+5
0000
0000
0000
0000
Saving in Controller
Stores the current system data and scene group in the controller.
Acesst 1.0 6251194
Содержание FZ3 Series
Страница 10: ...1 Before Operation 8 Operation Flow FZ3 User s Manual Operation Flow Operation flow is explained here...
Страница 28: ...1 Before Operation 26 Saving Settings and Turning Power Off FZ3 User s Manual...
Страница 60: ...2 Setting Scenes Measurement Flow 58 Editing Scene Groups FZ3 User s Manual...
Страница 106: ...4 Saving Loading Data 104 Loading Settings Data to Controller FZ3 User s Manual...
Страница 122: ...5 Changing the System Environment 120 Setting the System Operation Environment FZ3 User s Manual...