FZ3 User's Manual
Communicating through Serial Communication (PLC Link)
127
2.
In the communication setting area, set the following items.
Setting item
Set value
[Factory default]
Description
Interface
●
[RS-232C]
●
RS-422
Adjust to the PLC communication specifications.
Baud rate [bps]
[Note 1]
●
2400
●
4800
●
[9600]
●
19200
●
38400
●
57600
●
115200
Adjust to the PLC communication specifications.
Data length [bit]
●
[7]
●
8
Adjust to the PLC communication specifications.
Parity
●
None
●
Odd
●
[Even]
Stop bit [bit]
●
1
●
[2]
Flow control
[None]
Flow control is not performed with software.
If the time in which there is no response from
external devices reaches the timeout setting time,
a timeout error occurs and an error message is
displayed in the window.The parallel interface
ERROR signal also turns on.
Xon/Xoff
Flow control is performed with software.Data is
sent according to the Xon/Xoff codes from
external devices.
Acesst 1.0 6251194
Содержание FZ3 Series
Страница 10: ...1 Before Operation 8 Operation Flow FZ3 User s Manual Operation Flow Operation flow is explained here...
Страница 28: ...1 Before Operation 26 Saving Settings and Turning Power Off FZ3 User s Manual...
Страница 60: ...2 Setting Scenes Measurement Flow 58 Editing Scene Groups FZ3 User s Manual...
Страница 106: ...4 Saving Loading Data 104 Loading Settings Data to Controller FZ3 User s Manual...
Страница 122: ...5 Changing the System Environment 120 Setting the System Operation Environment FZ3 User s Manual...