Controlling/Outputting through Parallel Communication
FZ3 User's Manual
Item
Description
Input format (DI7 to DI0)
Input example
Execute
(DI7)
Command
(DI6, DI5)
Command information
(DI4 to 0)
Continuous
measurement
Measure continuously
during input of commands.
1
00
*****
The controller does
not see this signal, so
a setting of either 0 or
1 makes no difference.
Input Example:
10000000
Scene
switch
Switch measurement
scenes.
1
01
Input "Scene No." in
binary format.
Switch to scene
2.
Input Example:
10100010
Scene group
switch
Switch measurement
scene groups.
1
11
Input "Scene Group
No." in binary format.
Switch to scene
group 2.
Input Example:
11100010
Clearing
Measurement
Values
Clear measurement
values.
The OR signal and DO
signal are not cleared.
1
10
00000
Input Example:
11000000
Clear Error
Clear error output.
The ERROR indicator is
also cleared.
1
10
00001
Input Example:
11000001
Clear
Parallel
OR+DO
Clear the OR signal and
DO signal.
1
10
00010
Input Example:
11000010
0: OFF 1:ON
Note
●
When the input command is not received correctly, the ERROR signal turns on.
Important
●
During parallel continuous measurement and when the STEP signal is input continuously, do not perform
switching of the scene group. When this is performed, set "Unchecked" in "Save scene group on switch scene"
in either of the settings items below.
●
Switch Scene Group window Reference:
●
[Measure setting] in the [Measure] menu Reference:
Setting Conditions Related to Operation during Measurement (p.108)
Output Format
Each time measurement is performed, the measurement result is output.
Output can be selected to turn on either when the judgement result is OK or when it is an NG error.The
factory default setting is "ON at NG".
Reference:
Setting Communication Specifications (Parallel Interface) (p.178)
Signal
Output contents
OR Signal
Overall judgement results are output.
Acesst 1.0 6251194
Содержание FZ3 Series
Страница 10: ...1 Before Operation 8 Operation Flow FZ3 User s Manual Operation Flow Operation flow is explained here...
Страница 28: ...1 Before Operation 26 Saving Settings and Turning Power Off FZ3 User s Manual...
Страница 60: ...2 Setting Scenes Measurement Flow 58 Editing Scene Groups FZ3 User s Manual...
Страница 106: ...4 Saving Loading Data 104 Loading Settings Data to Controller FZ3 User s Manual...
Страница 122: ...5 Changing the System Environment 120 Setting the System Operation Environment FZ3 User s Manual...