6
M
eth
od
s
fo
rC
on
ne
ctin
g
an
d
C
om
m
un
ica
tin
g
w
ith
E
xte
rn
al
D
ev
ice
s
FZ3 User's Manual
Controlling/Outputting through Serial Communication (Non-procedure)
151
Example of input format (SCENE command)
Enter a delimiter at the end of commands.
In this manual, delimiters are expressed with "
".
Separate parameters with spaces. (Not required before delimiters.)
In the following cases, an error occurs. The system quits abnormally and the return values are returned
when an error occurs.
●
When non-existing commands are specified
●
The number of parameters is incorrect
●
The range of the parameters is incorrect
●
The content of parameters is incorrect
●
When action cannot be ended correctly with an action instruction command
Important
●
Commands can be input and measurement results can be output only when the Main screen is at the front.
Cannot receive commands when setting windows or the Edit flow windows are displayed (excluding "Serial" -
"Confirmation"). On the Main screen, even if the screen is switched to the Edit Flow window, etc., the data output
after measurement will not be interrupted before all data is output. Commands cannot be accepted when
windows other than the Main screen are displayed.
Command List (Non-procedure)
This section explains the input format for each command used in the serial normal method.
Commands are input with ASCII code.Both lowercase and uppercase letters can be used.
Scene control command
Command
Abbreviation
Function
References
SCENE
S
Acquires the current scene No.
Switches scene No. currently being used
SCNGROUP SG
Acquires the scene group No currently in use.
Switch the scene group No.
Measurement control/Measurement value acquisition commands
Command
Abbreviation
Function
References
MEASURE
M
Perform measurement once
Start continuous measurement
Complete continuous measurement
SCRSWITCH OFF
Switches the ADJUST window/RUN window
UNITDATA
UD
Acquires the parameters and/or measurement values of specified
processing units
Sets the parameters of specified processing units
Acesst 1.0 6251194
Содержание FZ3 Series
Страница 10: ...1 Before Operation 8 Operation Flow FZ3 User s Manual Operation Flow Operation flow is explained here...
Страница 28: ...1 Before Operation 26 Saving Settings and Turning Power Off FZ3 User s Manual...
Страница 60: ...2 Setting Scenes Measurement Flow 58 Editing Scene Groups FZ3 User s Manual...
Страница 106: ...4 Saving Loading Data 104 Loading Settings Data to Controller FZ3 User s Manual...
Страница 122: ...5 Changing the System Environment 120 Setting the System Operation Environment FZ3 User s Manual...