Set the trigger detailed settings as required.
Setting item
Set value
[Factory default]
Description
Trigger signal
●
[Phase A]
●
Phase Z
Sets the trigger signal.
When phase A
Pulse reset
timing
●
[Every trigger pulse]
●
Every rotation (Pulse Z)
●
STEP
Sets the timing for resetting.
Phase A
[0] to 65536
Sets the pulse width.
Support
backlashing
●
[Checked]
●
Unchecked
Sets whether the rotation direction is
detected.
Trigger in
backlashing
●
Checked
●
[Unchecked]
Sets whether a trigger is produced
during reverse rotation.
When phase Z
Pulse reset
timing
●
[Every trigger pulse]
●
STEP
Sets the timing for resetting.
Phase Z
[0] to 1023
Sets the pulse width.
Setting the STEP Input Detection Pulse Width [STEP Setting]
This setting is performed as a countermeasure against STEP input chattering and to prevent operation
malfunctions due to entrance of noise.
When Filter Setting Value Is 100 μs (Initial Value)
The STEP signal is detected as being on at the point it is on continuously for at least 100 μs, and
measurement begins at this point.Accordingly, STEP signal detection is delayed by an amount of time
equivalent to the set filter value. Also, when turning from ON to OFF, the OFF filter fixed at 500 μs is
activated and the STEP signal is detected as OFF when it is off for at least 500 μs.
Acesst 1.0 6251194
Содержание FZ3 Series
Страница 10: ...1 Before Operation 8 Operation Flow FZ3 User s Manual Operation Flow Operation flow is explained here...
Страница 28: ...1 Before Operation 26 Saving Settings and Turning Power Off FZ3 User s Manual...
Страница 60: ...2 Setting Scenes Measurement Flow 58 Editing Scene Groups FZ3 User s Manual...
Страница 106: ...4 Saving Loading Data 104 Loading Settings Data to Controller FZ3 User s Manual...
Страница 122: ...5 Changing the System Environment 120 Setting the System Operation Environment FZ3 User s Manual...