6
M
eth
od
s
fo
rC
on
ne
ctin
g
an
d
C
om
m
un
ica
tin
g
w
ith
E
xte
rn
al
D
ev
ice
s
170
Controlling/Outputting through Serial Communication (Non-procedure)
FZ3 User's Manual
(Example)
When the image logging setting is acquired when the setting for acquiring the current image logging
save condition is 1 (save only for NG error)
<Command>
<Response>
The current image logging save condition is "1: Only NG".
Changes settings related to image logging
Changes setting related to current image logging.
<Command format>
<Response format>
When processing is performed normally
When processing is not performed normally
<Parameters explanation>
Setting data
Identifier 1
Set value
Image Logging
imageLogging
●
0: None
●
1: Only NG
●
2: All
Folder name of image logging save
destination
imageLoggingDirectory
Save destination folder name (one-byte alphanumeric
character)
Prefix for image logging file name
imageLoggingHeader
Prefix for image logging file name (one-byte
alphanumeric characters)
Data Logging
dataLogging
●
0: None
●
1: Only NG
●
2: All
Name of destination folder for
saving data logging
dataLoggingDirectory
Save destination folder name (one-byte alphanumeric
character)
Acesst 1.0 6251194
Содержание FZ3 Series
Страница 10: ...1 Before Operation 8 Operation Flow FZ3 User s Manual Operation Flow Operation flow is explained here...
Страница 28: ...1 Before Operation 26 Saving Settings and Turning Power Off FZ3 User s Manual...
Страница 60: ...2 Setting Scenes Measurement Flow 58 Editing Scene Groups FZ3 User s Manual...
Страница 106: ...4 Saving Loading Data 104 Loading Settings Data to Controller FZ3 User s Manual...
Страница 122: ...5 Changing the System Environment 120 Setting the System Operation Environment FZ3 User s Manual...