FZ3 User's Manual
Setting item
Set value
[Factory default]
Description
Command area
Area
●
[CIO Area(CIO)]
●
Work Area(WR)
●
Holding Bit Area(HR)
●
Auxiliary Bit Area(AR)
●
DM Area (DM)
●
EM Area(EMO)
Set the communication
area.
Address
0 to 99999
[0]
Set the communication
address.
Response area
Area
●
[CIO Area(CIO)]
●
Work Area(WR)
●
Holding Bit Area(HR)
●
Auxiliary Bit Area(AR)
●
DM Area (DM)
●
EM Area(EMO)
Set the communication
area.
Address
0 to 99999
[100]
Set the communication
address.
Data output area
Area
●
[CIO Area(CIO)]
●
Work Area(WR)
●
Holding Bit Area(HR)
●
Auxiliary Bit Area(AR)
●
DM Area (DM)
●
EM Area(EMO)
Set the communication
area.
Address
0 to 99999
[200]
Set the communication
address.
Retry interval [ms]
1000 to 999999
[10000]
Set the communication
retry interval.
5.
Tap [OK].
The settings are confirmed and the Ethernet window closes.
Checking Communication Status
Use PLC tools, etc. to check the communication status.
Setting Communication Specifications (RS-232C/422-PLC Link)
Communication specifications such as link areas or communication speed and data length are set.
Reference:
Setting Communication Specifications (Ethernet - PLC Link) (p.123)
Important
●
Before setting the communication specifications, set the "Serial (RS-232C/422) " communication module to
"PLC link (SYSMAC CS/CJ/CP/One) ", store to the controller, then restart the system.
Reference:
Setting the Start-up Status [Startup Setting] (p.112)
●
Use the same communication specification settings for the controller and the external device.
1.
On the Main screen, tap the [System] menu - [Communication] - [Serial] - [RS-232C/RS-422].
The serial interface window is displayed.
Acesst 1.0 6251194
Содержание FZ3 Series
Страница 10: ...1 Before Operation 8 Operation Flow FZ3 User s Manual Operation Flow Operation flow is explained here...
Страница 28: ...1 Before Operation 26 Saving Settings and Turning Power Off FZ3 User s Manual...
Страница 60: ...2 Setting Scenes Measurement Flow 58 Editing Scene Groups FZ3 User s Manual...
Страница 106: ...4 Saving Loading Data 104 Loading Settings Data to Controller FZ3 User s Manual...
Страница 122: ...5 Changing the System Environment 120 Setting the System Operation Environment FZ3 User s Manual...