166
Malfunction report
Not enough draught
ڃ
Check ventilation flap, funktion radial fan,
draught free
Flue gas sensor or flamm-
roomtemperature-sensor
soiled
ڃ
Check Flue gas sensor or flammroom-tem-
perature-sensor
Display:
[5036] PE Flame supervision fault
Description:
Flame supervision fault, minimum flue gas temperature not reached during
heating up at full power – Input FRT
Cause and Remedy:
No pellets available
ڃ
Fill up with pellets
13.15 Flame return gate BSK (5038, 5039, 5040)
Display:
[5038] PE Flame return gate open
Description:
Flame return gate open fault (BSK - 1 2)
Cause and Remedy:
Flame return gate
unplugged
ڃ
Connect up flame return gate and check
cable connections
Flame return gate does
not reach OPEN limit
switch
ڃ
Check ball valve to see if it is jammed
No signal although open
ڃ
Check cables and flame return gate
Display:
[5039] PE Flame return gate closed
Description:
Flame return gate open fault
Cause and Remedy:
Flame return gate
unplugged
ڃ
Connect up flame return gate and check
cable connections
Flame return gate does
not reach CLOSE limit
switch
ڃ
Check whether ball valve is jammed, check
ball valve throughway to see if foreign ob-
jects are preventing it from closing
No signal although closed
ڃ
Check cables and flame return gate
Display:
[5040] PE Flame return gate limit switch
Description:
Both flame return gate limit switches (BSK 1-2 and BSK 3-4) are closed at the
same time
Cause and Remedy:
Both limit switches
activated
ڃ
Check flame return gate, check cables,
check connectors
13.16 Suction system (Fault 5043)
Display:
Suction system
Description:
Hopper cannot be filled up even after 3 suction cycles
Cause and Remedy:
Storage room empty
ڃ
Fill up with pellets
Extraction system is
blocked
ڃ
Clear extraction system
Extraction system not con-
veying pellets
ڃ
Pellet bridge - destroy bridge and make sure
material flows properly
PE 567 EN 1.1
Содержание PE 08
Страница 16: ...16 Wiring diagrams PE 567 EN 1 1 ...
Страница 17: ...Wiring diagrams 17 Operating Manual PELLEMATIC PE S K B 10 56 ...
Страница 18: ...18 Wiring diagrams PE 567 EN 1 1 ...
Страница 76: ...76 Code Input Menu of Pelletronic Touch after entering the code PE 567 EN 1 1 ...
Страница 110: ...110 Cascade settings Back to the menu Sys Regulation PE 567 EN 1 1 ...
Страница 168: ......
Страница 169: ......