136
Settings
If a malfunction occurs, the boiler controller controls the relay fault signal.
The potential-free contact (Output SM 20 19) displays the malfunctions by using an
external display device. (1–230V).
You can choose the following functions:
On / Off:
By warning
Ash
or warning
Pellets
the contact closes.
1x:
If a malfunction occurs, the contact closes – Closer
By warning "Ash box full" appears a flashing pulse. (Contact closes once)
blinc:
Depending on the error, the malfunction contact gets switched with different
impulses.
Choose between 2 ways of exits:
Standard:
the exit is set when an error occurs.
Inverted:
the exit is set back when an error occurs. (Contact SM is opened)
Setting, if Pellematic is installed as a Hand filling hopper.
0 = inactive, 1 = active
Choose between 2 ways of entries:
Standard:
the boiler gets blocked, if contact AK is closed.
Inverted:
the boiler gets blocked if contact AK is open.
Activate the capacitive sensor on the burner.
0 = inactive
Activate the capacitive sensor on the hopper.
0 = inactive, 1 = active
Back to the menu
Pellematic
.
PE 567 EN 1.1