70
Performance adjustment
13.1 Performance adjustment
The heat exchanger of an ÖkoFEN pellet boiler is changeable in every assembly.
That can be made by opening or closing of the heat exchanger pipes. So the power rating is adjustable.
If the delivery condition varies from the enclosed data plate, the service technician has to adjust the power ra-
ting before the initial start up.
13.2 Setting the adresses of the Bus-participants
Before the boiler controller gets connected to the power supply, they have to be adressed.
M
Ma
atte
erriia
all D
Da
am
ma
ag
ge
e
Adjustments with the adress switch are only possible if
the whole system is powerless.
113
3..2
2..11 S
Se
ettttiin
ng
g tth
he
e a
ad
dd
drre
es
ss
s a
att tth
he
e b
bu
urrn
ne
err c
co
on
nttrro
olllle
err
The burner controller has an address switch.
If operating a cascade system this address switch must be set accordantly.
Note:
The screwdriver for adjustment of the adress adder is enclosed to delivery of the boiler controller..
PE 567 EN 1.1
Содержание PE 08
Страница 16: ...16 Wiring diagrams PE 567 EN 1 1 ...
Страница 17: ...Wiring diagrams 17 Operating Manual PELLEMATIC PE S K B 10 56 ...
Страница 18: ...18 Wiring diagrams PE 567 EN 1 1 ...
Страница 76: ...76 Code Input Menu of Pelletronic Touch after entering the code PE 567 EN 1 1 ...
Страница 110: ...110 Cascade settings Back to the menu Sys Regulation PE 567 EN 1 1 ...
Страница 168: ......
Страница 169: ......