Software Update
153
Firmware Update — Approach:
1.
Switch off the complete heating system.
2.
Plug in the USB flash drive with the new software in the back of the slot:
USB 0
of the heating
controller.
Note:
Use only suitable USB-sticks. (no wooden ÖkoFEN USB-sticks)
3.
Place the touch operating device in the control panel.
4. Switch on the heating controller.
While booting up, software update of operating devicede starts automatically
Begin with the update of all Touch remote controls and operating devices.
5.
Go to the
CODE
button, enter the code to reach the level settings.
6. Go to the button
Software
7.
Choose
Update
Note:
If you have forgotten to insert the USB stick - Press the
Refresh
button (wait about 1min)
8.
All components can be selected at the same time.
9. Press the Button
Update
and reply to the query with
YES
.
After all components are updated, disconnect all from the power supply, reconnect and then restart them
to produce the bus connection again.
113
3..117
7..4
4 S
So
offttw
wa
arre
e U
Up
pd
da
atte
e
First perform a software download. In the ÖkoFEN download area is always the current software available for
downloading.
Link: http://ftp.pelletsheizung.at
For access information, please contact your ÖkoFEN representation.
Operating Manual PELLEMATIC® PE(S)(K)(B) 10 — 56
Содержание PE 08
Страница 16: ...16 Wiring diagrams PE 567 EN 1 1 ...
Страница 17: ...Wiring diagrams 17 Operating Manual PELLEMATIC PE S K B 10 56 ...
Страница 18: ...18 Wiring diagrams PE 567 EN 1 1 ...
Страница 76: ...76 Code Input Menu of Pelletronic Touch after entering the code PE 567 EN 1 1 ...
Страница 110: ...110 Cascade settings Back to the menu Sys Regulation PE 567 EN 1 1 ...
Страница 168: ......
Страница 169: ......