Heating Circuit
91
13.7 Heating Circuit
Appropriate to the amount of existing heating circuits, for every HC a menu item (Icon) is displayed.
Heating circuits settings has following menu
items:
• Operating Mode
• External request
• Room Temp Heating
• Room Temp Set Down
• Time Selection
• Display name
• Values
• Time 1
• Time 2
• Party
• Vacation
• Heating curve
In this submenu, you can set customer-specific adjustments.
Detailed information are in the Manual for the End User.
More adjustments for the ÖkoFEN Service technician:
Is the upper limit of the flow temperature, even if due to the outside temperature a
higher flow temperature would be needed.
Is the lower limit of the flow temperature, even if due to the outside temperature a
lower flow temperature would be needed.
This is the temperature value, which is added to the flow temperature set.
If the calculated flow temperature set is 60°C and the reinforcement is 5°C, the ac-
cumulator temperatur set is 65°C.
If the measured boiler temperatur or the temperature of accumulator sensor high
(TPO) is lower, the heating controller initiates a burner request.
Choose the type of heating circuit
• HC with a mixermotor
• direct HC
Operating Manual PELLEMATIC® PE(S)(K)(B) 10 — 56
Содержание PE 08
Страница 16: ...16 Wiring diagrams PE 567 EN 1 1 ...
Страница 17: ...Wiring diagrams 17 Operating Manual PELLEMATIC PE S K B 10 56 ...
Страница 18: ...18 Wiring diagrams PE 567 EN 1 1 ...
Страница 76: ...76 Code Input Menu of Pelletronic Touch after entering the code PE 567 EN 1 1 ...
Страница 110: ...110 Cascade settings Back to the menu Sys Regulation PE 567 EN 1 1 ...
Страница 168: ......
Страница 169: ......