In case a remote control(E1396) was installed, it has to be adressed.
How to configurate the remote controll
allocation of heating circuits:
• Hold both arrows
ٻڅ
at the same time for ca. 4 seconds until LED
blinks yellow.
• Now adjust the heat circuit number with the
–
and
+
buttons.
• The amount of green LEDs on the left top corner is equal to the adjusted heating circuit number.
e.g.: If 3 LEDs are lightning, heating ciruit number 3 is allocated.
• Hold both arrows
ٻڅ
again for about 4 minutes after the desired adjustment was made.
• In case of yellow light of the LED, the heating circuit number is taken over.
Afterwards the LED light changes to green.
Wait until the green blinking ends, then adjust all remote controls to the equevalent heating circuits.
Periphery learning
After adjusting all remote controls to their heating circuits, you have to run
periphery learning
on the opera-
ting device. After Periphery learning the heating circuit recognizes all to the system connected devices and
sensores. If a heating circuit is connected to a remote control is to be seen in the menu item measuring values
at
room temp
. If no remote control is conected to the sensor, an empty field is displayed.
PE 567 EN 1.1
Содержание PE 08
Страница 16: ...16 Wiring diagrams PE 567 EN 1 1 ...
Страница 17: ...Wiring diagrams 17 Operating Manual PELLEMATIC PE S K B 10 56 ...
Страница 18: ...18 Wiring diagrams PE 567 EN 1 1 ...
Страница 76: ...76 Code Input Menu of Pelletronic Touch after entering the code PE 567 EN 1 1 ...
Страница 110: ...110 Cascade settings Back to the menu Sys Regulation PE 567 EN 1 1 ...
Страница 168: ......
Страница 169: ......