VOLT:UVL {<numeric value>}
This command sets the under voltage limit level.
0V ~ currently setting value.(up to voltage setting value).
ex) volt 10
At first set the voltage value
volt:uvl 5
Set lower value than above setting value
From the time set UVL, you can not set the voltage to below 5V.
VOLT:UVL?
This query returns the under voltage limit value presently programmed.
Return value
return value "5.00"
VOLT:OVL?
This command sets the over voltage limit level.
Currently setting value~miximum of limit value.
At first set the voltage value
volt:ovl 15
Set the higher value than above setting value
From the time set OVL, you can not set the voltage to above 15V.
VOLT:OVL?
This query returns the under voltage limit value presently programmed.
Return value
"numeric value"
return value "15.00"
CURR {<current>|UP|DOWN}
This command programs the immediate currenr level of the power supply. The immediate level is
the current value of the output terminals.
This command also increases or decreases the immediate current level using the ‘‘UP’’ or
‘‘DOWN’’ parameter by a predetermined amount. The command CURRent:STEP sets the amount
of increase or decrease.
> current
Input current value.
> UP
Increase current setting value as step value.
> DOWN
Decrease current setting value as step value.
ex1) curr 4.5
Set the current 4.5A
ex2) curr up
Increase current setting value as step value
If you operated "*RST" command, current step value returned to the unit's default value.
About "*RST" command, refer to "*RST" command chapter.
> numeric value
ex) volt:ovl?
ex) volt:uvl?
> numeric value
ex) volt 10
Note
- 77 -