1. General Information
1-1. Feature
EX Series Single Output products are high-performance and high-efficiency programmable DC power
supply with RS-232C, RS-485, TCP/IP(option) interface based on SCPI (Standard Commands for
Programmable Instruments) protocol and the combination of bench-top and system features in these
power supplies provides versatile solutions for your design and test requirements in the industiral fields,
R&D institute center and education fields.
General Feature
▌
Easy-to-use knob control settings.
▌
2-Line * big size16Character LCD Display.
▌
Output ON/OFF key.
▌
Front panel key lock function.
▌
Alarm beep when events occure.
▌
Excellent precise and high resolution
▌
Built-in Remote Sensing for Load Voltage(V-Sensing)
▌
O.V.P(Over Voltage Protection) / O.C.P(Over Current Protection) mode supplied.
▌
U.V.L(Under Voltage Lock) O.V.L( Over Voltage Lock) value setting functions.
▌
U.C.L(Under Current Lock), O.C.L(Over Current Lock) value setting functions.
▌
Excellent load and line regulation
▌
Save Memory(operating state of voltage, current, OVP,OCP) and recall up to 10
▌
Save and confirm up to 10 error messages
▌
19inch Rack Compact Size (600~2.5KW-1U, 2.5~5KW-2U, 5~10KW-4U)
▌
High-efficient output of 80%~90%.
Characteristics of Remote Interface
▌
Supply various interface - RS-232C, RS-485, TCP/IP(option)
▌
compatible with SCPI(Standard Commands for Programmable Instruments)
▌
High speed setting & measurement
▌
Programmed in abundant commands in the instrument.
▌
Easy interface setting with "I/O config" on front panel key
▌
Technical realization of products insulation & Floating Logic
▌
Buint-in the error checking function for SCPI programming grammer.
Calibration
▌
Software Calibration by manual with PC (No need of opening cover of instrument for calibration)
▌
Easy calibration by using independence or PC interface
Factory Function
▌
Initialization function of 10 user memory
▌
Save and Recall last state of the instrument before turned off
▌
The function of "Auto Key Lock & Auto Cursor Move" to prevent operator's mistake
▌
OVP & OCP disable or disable setting function.
▌
LCD display speed control function of V/I value by using "ADC(Analog to Digital Conversion)
Sampling" function.
▌
Calibration Recall Function
▌
Calibration Back-Up function
- 10 -