FACT:OVP {DIS|ENA}
Enable or disable the "Over Voltage Protection" function.
> DIS
Disable "OVP USE" mode.
> ENA
Enable "OVP USE" mode.
Set the disable "OVP" function.
FACT:OVP?
Confirm OVP function value.
Return value
"0"
Disable state
"1"
Enable state
ex)fact:ovp?
return value "0"
FACT:OCP {DIS|ENA}
Enable or disable the "Over Current Protection" function.
> DIS
Disable "OCP USE" mode.
> ENA
Enable "OCP USE" mode.
Set the disable "OCP" function.
FACT:OCP?
Confirm OCP function value.
Return value
"0"
Disable state
"1"
Enable state
ex)fact:ocp?
return value "0"
FACT:ADC {5|20|50|100|300|1300}
Be able to set the output voltage/current measuring speed and displaying speed.
> 5
Measures voltage/current at every 5 times/1sec, measure very precise value.
> 20
Measures voltage/current at every 20 times/1sec, measure very precise value.
> 50
Measures voltage/current at every 50 times/1sec, measure precise value.
> 100
Measures voltage/current at every 100 times/1sec, measure precise value.
> 300
Measures voltage/current at every 300 times/1sec, measure value in fast.
> 1300
Measures voltage/current at every 1300 times/1sec, measure value in fast.
ex) fact:ADC 5
Sampling speed is slow but you can read precise value.
FACT:ADC?
Confirm ADC Sampling speed.
Return value
"5Hz"
5 times/1sec sampling time
"20Hz"
20 times/1sec sampling time
"50Hz"
50 times/1sec sampling time
"100Hz"
100 times/1sec sampling time
"300Hz"
300 times/1sec sampling time
"1.3KHz"
1300 times/1sec sampling time
ex)fact:ADC?
return value "5Hz"
ex) fact:ocp dis
ex) fact:ovp dis
- 83 -
Содержание EX 100-12
Страница 1: ...Programmable DC Power Supply User Manual www odacore com EX Series Manual Part NO 019EX 03...
Страница 4: ...Safety Symbol...
Страница 91: ...92...
Страница 92: ...93...