Delimiter
You can choice the sending and responsing data delimiter among LF, CR and CRLF and when we are shipped,
default value is LF. Next is setting procedure
▌
Turn on the power supply
After turned on, check the power supply displays"**OUTPUT OFF**" Mode.
▌
In order to change the delimiter, press the "IO/Local" key
LCD Display
Or it is differ following before state.
▌
Press the cursor key until reaching "5.delimiter".
LCD Display
▌
If you want to change the delimiter to "CR", press the "IO/Local" key.
LCD Display
Or it is differ following before state.
▌
In order to select "CR", press the cursor key and move to "delimiter cr"
After appear "delimiter cr"message, press the "IO/Local" key, after then
appear "SAVED" message.
LCD Display
SAVED
Response
You are able to have the response when you send the commennd to power supply.
When shipped, response function is clear state.
▌
Turn on the power supply
After turned on, check the power supply displays"**OUTPUT OFF**" Mode.
▌
In order to change "Respons" enable or disable, press the "IO/Local" key.
Or it is differ following before state.
▌
Press the cursor key until reaching "5.delimiter".
▌
In order to change the "Response" enable, press the "IO/Local" key.
▌
Press the cursor key until appearing "response yes" message
And in order be enable, press the "IO/Local" key.
- 48 -
>I/O > 6. response
LCD Display
>I/O > 1.RS-232C
LCD Display
Response yes
>Response no
LCD Display
LCD Display
I/O>
>delimiter lf
delimiter
SAVED
delimiter