1-6. Check After Power On
The power-on test includes an automatic self-test that checks the internal microprocessors and allows
the user visually to check the display. You will observe the following sequence on the display after pressing
the front panel power switch to on. And also keep the ex-remote and voltage value is zero and current value
is max value. OVP & OCP level are set to maximum output value of instrument capacity and it is under
the vigilance.
Display the prpcedure the LCD
▌
Display "ODA Technologies".
▌
Display "EX-Series Ver1.3"
▌
Annunciators of ERR,LMT,RMT,LOCK on front side are lit and go off clockwise from the left.
CV & CC annunciators are not applied.
▌
During displaying above procedure, the instrument is initialized by stored in non-volatile memory
▌
Also the instrument runs automatic self-test below mentioned. Connection test between front panel
Connection test between front panel and connector.
Remote interface Test
Check remote interface for PC communication.
Memory data confirm Test
Check product information and related setting.
ADC H/W error Test
Check error on ADC control condition.
UnRegulated state Test
Check output voltage floating state
ADC/DAC Calibration Test
check ADC & DAC Calibration data state
If the error occurs, alarm beeps and the error code is saved to volatile memory automatically.
You can read the error code by pressing error key. About error code explanation, refer to
“7. Error Messages”.
Default Setting Values (Last state Mode is under the Disable state )
▌
OVP : OVP value is max, state is ON
▌
Remote Interface : RS-232C
▌
OCP : OCP value is max, state is ON
▌
State after self-test : "**OUTPUT OFF**"
▌
UVL : 0V
▌
Cursor location : Default voltage select
▌
OVL : Limit setting maximum value
Voltage : 1V
▌
UCL : 0A
Current : 100mA if current is under 5A.
▌
OCL : Limit setting maximum value
In case of under 50A : 1A
▌
Output Voltage : 0V
In case of under 100A : 10A
▌
Output Current : Limit setting maximum v
▌
KEY LOCK : OFF
Remote Interface default is RS232C and the rate is set to 9600 baud when the power supply is shipped
from the factory. TCP/IP Module is optional and bulit in type.When ordering, please request.
In case of "Last State", it is disable when the power supply is shipped from the factory.
If you want to use this function, it is able to use in "Factory Mode". Refer to "5-4. Last State"
Note1
Note2
- 15-
Front panel Te