10.28 USB Memory Interface
KP3000GS
247
10.28 USB Memory Interface
Commercial USB memory sticks can be used.
Description
Available memory
*49 USB 1.1 or USB 2.0-compliant product
Connector USB-A
(front
panel)
Format FAT32
Writable/readable contents Basic Setting Memory, Sequence, Simulation, arbitrary wave
File operation
*50 Create dedicated directory, rename, load, and save
2-byte characters (Japanese, etc.) are not supported,
*49: We do not guarantee that all USB memories can be operational with this product.
*50: The time stamp recorded on a file is different from the actual date and time.
10.29 Waveform Monitor Output
This can monitor the waveform of the output voltage or current. (only one terminal)
KP3000GS
Monitored
Output voltage or output current (switched)
Gain voltage
200
1
/
400
1
current
*51 100
1
/
50
1
Accuracy *52
5 %
Output terminal
BNC connector (rear panel, unbalanced)
Output impedance
600
*51: When you set the number of units by the power unit energization setting to 1, the current gain
doubles.
*52: No load on the monitor output, the rated output voltage, the resistance load at the maximum
current.
10.30 Safety and EMC
Except for LAN interface selected.
Description
Safety
*53 Compliant with the following standard requirement.
EN 61010-1:2010
Pollution Degree 2
EMC
*53 *54 *55 Compliant with the following standard requirement.
EN 61326-1:2013 (Group 1, Class A)
RoHS
*53*56 Compliant with the following.
Directive 2011/65/EU
*53: Only Models with a CE Marking on the Rear Panel.
*54: Current limiter operation or indication malfunction of LEDs or measured values may occur if
the KP3000GS is exposed to a strong radiated radio frequency electromagnetic field or a strong
radio frequency conducted disturbance.
*55: Electromagnetic emissions from this product may interfere with reception of radio and
television broadcasts. Unless the user takes special measures to reduce electromagnetic
emissions, using this product in a residential area must be avoided.
*56: For compliant manufacturing lot, please contact us or our agent.
Содержание KP3000GS
Страница 1: ...PROGRAMMABLE AC DC POWER SOURCE KP3000GS INSTRUCTION MANUAL...
Страница 2: ......
Страница 3: ...DA00033845 005 PROGRAMMABLE AC DC POWER SOURCE KP3000GS INSTRUCTION MANUAL...
Страница 4: ......
Страница 5: ......
Страница 19: ......
Страница 20: ...KP3000GS 1 1 Outline 1 1 Overview 2 1 2 Features 2...
Страница 23: ......
Страница 197: ......
Страница 198: ...KP3000GS 179 5 Description of Screen and Menu 5 1 Screen Configuration 180 5 2 Menu Composition 184...
Страница 207: ......
Страница 208: ...KP3000GS 189 6 Remote Control 6 1 Communication Interface 190 6 2 Remote Local State Switching 199...
Страница 219: ......
Страница 224: ...KP3000GS 205 8 Troubleshooting 8 1 Error Messages and Error Handling 206 8 2 When a Failure is Suspected 213...
Страница 243: ......
Страница 275: ......
Страница 277: ......
Страница 278: ......
Страница 279: ...http www nfcorp co jp NF Corporation 6 3 20 Tsunashima Higashi Kohoku ku Yokohama 223 8508 JAPAN...