10.5 AC Output
KP3000GS
229
10.5 AC
Output
[V]=Vrms, [A]=Arms, and the power input voltage is 200 V, unless otherwise noted.
KP3000GS
Mode Single-phase
two-wire
Floating output, the Lo terminal can be grounded.
Rated output voltage
100 V / 200 V
Voltage setting range
0.0 V to 155.0 V / 0.0 V to 310.0 V
0.0 Vp-p to 440.0 Vp-p / 0.0 Vp-p to 880.0 Vp-p (arbitrary wave)
Setting
resolution 0.1
V
Voltage accuracy
*1
(0.5 % of set + 0.6 V / 1.2 V)
Maximum current *2
Maximum peak
current *3
Peak value (Apk) which is four times of the maximum current
Power capacity
3 kVA
Load power factor
0 to 1 (Phase lead or phase lag, 45 Hz to 65 Hz, external power injection or
regeneration are not available.)
Frequency
setting range
40.00 Hz to 550.00 Hz (AC mode)
1.00 Hz to 550.00 Hz (AC+DC mode)
Setting resolution
0.01 Hz
Frequency accuracy
0.01 % of set (23 °C
5 °C)
Frequency stability *4
0.005 %
Voltage frequency
characteristic *5
Output waveform
sine wave, arbitrary wave (16 types), clipped sine wave (3 types)
Output on phase
setting range
0.0° to 359.9° variable
Setting
resolution 0.1°
Output off phase
setting range
0.0° to 359.9° variable (active/inactive selectable)
Setting
resolution 0.1°
DC offset
*6 Within
20 mV (typ., fine adjustment available.)
*1: In the case of 10 V to 150 V / 20 V to 300 V, sine wave, no load, 45 Hz to 65 Hz, DC voltage
setting 0 V, 23 °C
5 °C.
*2: If the output voltage is higher than the rated value, this is limited (lowered) to satisfy the power
capacity. If there is the DC superimposition, the active current of AC+DC satisfies the maximum
current. In the case of 40 Hz or lower or 400 Hz or higher, and that the ambient temperature is
40 °C or higher, the maximum current may decrease.
*3: For the capacitor input type rectified load (crest factor=4), the rated output voltage, and 45 Hz to
65 Hz.
*4: For 45 Hz to 65 Hz, the rated output voltage, no load and the resistance load for the maximum
current, and the operating temperature.
*5: For 40 Hz to 550 Hz, sine wave, the rated output voltage, the resistance load for the maximum
current at 55 Hz, and 55 Hz reference.
*6: In the case of the AC mode and 23 °C
5 °C.
Содержание KP3000GS
Страница 1: ...PROGRAMMABLE AC DC POWER SOURCE KP3000GS INSTRUCTION MANUAL...
Страница 2: ......
Страница 3: ...DA00033845 005 PROGRAMMABLE AC DC POWER SOURCE KP3000GS INSTRUCTION MANUAL...
Страница 4: ......
Страница 5: ......
Страница 19: ......
Страница 20: ...KP3000GS 1 1 Outline 1 1 Overview 2 1 2 Features 2...
Страница 23: ......
Страница 197: ......
Страница 198: ...KP3000GS 179 5 Description of Screen and Menu 5 1 Screen Configuration 180 5 2 Menu Composition 184...
Страница 207: ......
Страница 208: ...KP3000GS 189 6 Remote Control 6 1 Communication Interface 190 6 2 Remote Local State Switching 199...
Страница 219: ......
Страница 224: ...KP3000GS 205 8 Troubleshooting 8 1 Error Messages and Error Handling 206 8 2 When a Failure is Suspected 213...
Страница 243: ......
Страница 275: ......
Страница 277: ......
Страница 278: ......
Страница 279: ...http www nfcorp co jp NF Corporation 6 3 20 Tsunashima Higashi Kohoku ku Yokohama 223 8508 JAPAN...