10. Specifications
PROGRAMMABLE AC/DC POWER SOURCE
242
10.22.3 External Signal Input (only EXT and ADD)
This multiplies the input signal by the specified gain and outputs it. For ADD, the internal signal
source is added.
EXT: Output voltage (V) = External signal input (V)
Gain (V/V)
ADD: Output voltage (V) = External signal input (V)
Gain (V/V)
+ Internal signal source setting (V)
KP3000GS
Factory default
Setting Range for gain
100 V range: 0.0 to 220.0 times
100
200 V range: 0.0 to 440.0 times
200
Setting resolution
0.1
Gain accuracy
*36
5 %
(DC, 45 Hz to 65 Hz, the gain is the factory default, the rated output
voltage, no load)
Input-output phase
In-phase
Input terminal
BNC connector (rear panel, unbalanced)
Also used as the external synchronization signal input
Input impedance
1 M
Input voltage range
2.2 V (A/D resolution 10 bit)
Nondestructive
maximum input voltage
10 V
Input frequency range
DC to 550 Hz (sine wave)
DC to 100 Hz (other than sine wave)
*36: DC or 45 Hz to 65 Hz, the gain is the factory default, the rated output voltage, no load.
10.23 General Function
Description
Factory default
LCD display
setting
Contrast
0 to 99
Color
Blue tone or white tone
White tone
Beep (key operation,
erroneous operation)
On or Off
Alarms on abnormal situation regardless of the
setting
On
Key lock
On or Off
On: Only key lock-off and output-off are available
Off
Output relay control
Enable: The output relay is used to turn the output
on/off
Disable: The output relay is not used. High
impedance to turn the output off
Enable
Output setting at power-on On or Off
On: Output on after power-on
Off
Trigger output setting
Polarity: positive
or negative
Pulse width: 0.1 ms to 10 ms (resolution 0.1 ms)
Negative
10 ms
Time unit setting for
Sequence and Simulation
ms or s
s
Reset function
Resets the items stored in the System Setting Memory (excluding the
external interface setting) and the items that are to be reset at power-on,
to the factory default settings.
Содержание KP3000GS
Страница 1: ...PROGRAMMABLE AC DC POWER SOURCE KP3000GS INSTRUCTION MANUAL...
Страница 2: ......
Страница 3: ...DA00033845 005 PROGRAMMABLE AC DC POWER SOURCE KP3000GS INSTRUCTION MANUAL...
Страница 4: ......
Страница 5: ......
Страница 19: ......
Страница 20: ...KP3000GS 1 1 Outline 1 1 Overview 2 1 2 Features 2...
Страница 23: ......
Страница 197: ......
Страница 198: ...KP3000GS 179 5 Description of Screen and Menu 5 1 Screen Configuration 180 5 2 Menu Composition 184...
Страница 207: ......
Страница 208: ...KP3000GS 189 6 Remote Control 6 1 Communication Interface 190 6 2 Remote Local State Switching 199...
Страница 219: ......
Страница 224: ...KP3000GS 205 8 Troubleshooting 8 1 Error Messages and Error Handling 206 8 2 When a Failure is Suspected 213...
Страница 243: ......
Страница 275: ......
Страница 277: ......
Страница 278: ......
Страница 279: ...http www nfcorp co jp NF Corporation 6 3 20 Tsunashima Higashi Kohoku ku Yokohama 223 8508 JAPAN...