2.2 About Installation Environment
KP3000GS
7
Install the product on a sturdy place.
The floor needs to have enough strength to support the weight of this product. The mass of this
product is shown in Table 2-3.
Table 2-3 Mass
Mass
KP3000GS
50 kg approx.
Do not install this product on a sloped surface. The Adjuster Foot is only for temporary fixing,
and cannot support the unit's own weight. You also must not lean on this product or use it as a
support. How to use the Adjuster Foot is shown in Figure 2–1.
Up
Down
Adjuster Foot
Figure 2-1 How to Use the Adjuster Foot
About arrangement
Do not place the product on its side, back or top.
Do not stack the product on top of the other, or place it in front or back of the other
(arrangement which makes the cabinet placed behind inhale the exhaust heat of the other).
Other installation location conditions
Use the product indoors, at altitude up to 2000 m.
Use the product where the temperature is 0 to +50 degrees Celsius, and the humidity is 5 to
85 %RH (the absolute humidity should be 1 to 25 g/m
3
, without condensation). However, on
some specifications, the temperature range limit is stricter.
Do not install the product in the following places:
Place exposed to inflammable gas
This may pose a risk of explosion. Never install and use the product in such a place.
The Adjuster Foot can be moved
up by turning it to left
(counterclockwise) as viewed from
above, and moved down by turning
it to right (clockwise). Move the
Adjuster Foot down by using a
spanner (19mm diameter).
Содержание KP3000GS
Страница 1: ...PROGRAMMABLE AC DC POWER SOURCE KP3000GS INSTRUCTION MANUAL...
Страница 2: ......
Страница 3: ...DA00033845 005 PROGRAMMABLE AC DC POWER SOURCE KP3000GS INSTRUCTION MANUAL...
Страница 4: ......
Страница 5: ......
Страница 19: ......
Страница 20: ...KP3000GS 1 1 Outline 1 1 Overview 2 1 2 Features 2...
Страница 23: ......
Страница 197: ......
Страница 198: ...KP3000GS 179 5 Description of Screen and Menu 5 1 Screen Configuration 180 5 2 Menu Composition 184...
Страница 207: ......
Страница 208: ...KP3000GS 189 6 Remote Control 6 1 Communication Interface 190 6 2 Remote Local State Switching 199...
Страница 219: ......
Страница 224: ...KP3000GS 205 8 Troubleshooting 8 1 Error Messages and Error Handling 206 8 2 When a Failure is Suspected 213...
Страница 243: ......
Страница 275: ......
Страница 277: ......
Страница 278: ......
Страница 279: ...http www nfcorp co jp NF Corporation 6 3 20 Tsunashima Higashi Kohoku ku Yokohama 223 8508 JAPAN...