Troubleshooting 8-5
ERROR MESSAGES
If an error occurs in the workstation, an error message appears on the display unit connected to the
workstation.
Powering on the workstation automatically starts the self-diagnostic program, POST (Power On
Self-Test). When the POST detects any error, it displays an error message and its measure on the
display unit.
IMPORTANT:
Take a note on the on-screen message before
contacting your service representative. The alarm indication would be a
great help for maintenance.
POST Error Messages
When POST detects an error, it displays an error message on the display unit screen. The following
table lists error codes, error messages, and actions to take.
IMPORTANT:
Take a note on the messages displayed before
consulting with your service representative. Alarm messages are useful
information for maintenance.
Error
code
Error message
Recommended Action
0200
Failure Fixed Disk
Contact your service representative.
0210
Stuck Key
Disconnect the keyboard and connect it again.
0211
Keyboard error
0212
Keyboard Controller Failed
Disconnect the keyboard and connect it again.
Restart the system. If the same error persists, contact
your service representative.
0250
System battery is dead - Replace
and run SETUP
Contact your service representative to replace the
battery. (After restarting the computer, run BIOS
SETUP to provide the setting again.)
0251
System CMOS checksum bad -
Default configuration used
The default values have just been set. Run BIOS
SETUP to provide the setting again.
0260
System timer error
0270
Real time clock error
0271
Check date and time settings.
Run BIOS SETUP to set the date and time again. If the
same error occurs successively in spite of the resetting,
contact your service representative.
02D0
System cache error - Cache
disabled
The cache cannot be used. Contact your service
representative.
0B20
NVRAM cleared by jumper
Set the jumper switch to the CMOS protect position.
0B21
Password cleared by jumper
Set the jumper switch to the Password protect position.
Run BIOS SETUP and set the password again.
0B28
Unsupported CPU detect on CPU
Socket
Contact your service representative to replace the CPU
that the workstation supports.
0B30
FAN1 Alarm occurred
0B32
FAN3 Alarm occurred
Remove the dust from the fan if clogged. If the same
error persists, contact your service representative.
0B60
DIMM1 has been disabled
0B61
DIMM2 has been disabled
Contact your service representative.
Содержание Express5800/53La
Страница 1: ...NEC Express5800 53La User s Guide 1st Edition 11 2010 ONL 550_009_02_53La 100 99 1011 ...
Страница 30: ...1 16 Notes on Using Your Workstation This page is intentionally left blank ...
Страница 35: ...General Description 2 5 Rear View 1 3 2 4 5 6 7 8 9 10 1 10 2 10 3 10 4 16 17 15 10 5 10 6 11 12 14 13 ...
Страница 56: ...2 26 General Description This page is intentionally left blank ...
Страница 120: ...4 48 Configuring Your Workstation This page is intentionally left blank ...
Страница 166: ...6 8 Installing and Using Utilities 4 Click Parameter File Creator Parameter File Creator will appear ...
Страница 252: ...A 2 Specifications This page is intentionally left blank ...
Страница 256: ...B 4 Other Precautions This page is intentionally left blank ...
Страница 279: ...Installing Windows 7 D 21 6 When following window is displayed click Yes 7 Click Important message is displayed ...
Страница 311: ...Installing Windows XP E 23 3 Process Windows activation according to the following message ...