Operation and Maintenance
652
Displaying Test Device List
Use
<list>
command to display the list of test devices.
Test Device List is displayed in the tree structure. The tree shows the installed position of
hardware. Except all the memory in the system is displayed in one lump.
The following is an example of screen using the command.
·
The test device list is displayed in the tree structure corresponding to the installed position of
hardware.
· In
the
“Num”
row, the test device number of the test device is displayed. Specify the test
device using these test device number.
· In
the
“*”
row, selected test is displayed in
“*.”
If not selected, the test is displayed in
“ ”
(blank). If
“!”
is displayed on a device, it is unselectable as the test device.
· In
the
“Device List”
row, the device name of the test device is displayed.
·
No device is selected for the test device on the initial status just after starting the TeDoLi.
· The device information on the lower layer can be collapsed with
<close>
command for the
tree that
“-”
is added on the top of the device name.
· The device information on the lower layer can be expanded with
<open>
command for the
tree that
“+”
is added on the top of the device name.
· The test device type is displayed in the
“Type”
row. On this type, the test device can be
selected by using
<select/desel>
command.
· In
the
“Prev”
row, the most recently executed test result is displayed.
· In
the
“Status”
row, the current test status is displayed.
TeDoLi> list
+----+-+---------------------------------+------------+----+-------------+
| Num|*| Device List | Type |Prev| Status |
+----+-+---------------------------------+------------+----+-------------+
| 1| | MEMORY |MEMORY | | |
| 2|!|-MGM2 |MODULE | | |
| 3|!| -MGM2/MGB/GbE |NIC | | |
| 4| | Port1(eth1) |ETH-PORT | | |
| 5| | Port2(eth2) |ETH-PORT | | |
| 6|!|-PMM5 |MODULE | | |
| 7| | PMM5/PMB/PROC |CPU | | |
| 8|!|-PMM6 |MODULE | | |
| 9| | PMM6/PMB/PROC |CPU | | |
| 10|!|-BM |MODULE | | |
| 11|!| -BM/MB/PCI1 |SCSI(NoDev) | | |
| 12|!| Port1 |SCSI-PORT | | |
| 13|!| -BM/MB/PCI8 |NIC | | |
| 14| | Port1(eth0) |ETH-PORT | | |
| 15|!| -BM/MB/PCI9 |FC | | |
| 16|!| -Port1 |FC-PORT | | |
| 17| | SCSI-ID0 LUN0(iStorage 1000) |HDD | | |
| 18|!| Port2 |FC-PORT | | |
| 19| | DV-28S-V |DVD | | |
+----+-+---------------------------------+------------+----+-------------+
Содержание Express 5800
Страница 73: ...73 Memo ...
Страница 279: ...Hardware 279 3 BIOS Menu screen is displayed ...
Страница 336: ...Hardware 336 Display Screen for WebBIOS Physical Drives Property Screen for Universal RAIDUtility Physical Devices ...
Страница 339: ...Hardware 339 3 BIOS will start Select Save Exit then press Enter ...
Страница 365: ...Hardware 365 6 Select Home at the lower left of the screen and press Enter to go back to WebBIOS Home Menu ...
Страница 444: ...444 Part Number Part number FRU File ID FRU file ID Asset Tag Asset management tag ...
Страница 526: ...526 Then input User Name for Authentication and select Keyboard interactive Then input Password ...
Страница 573: ...573 Memo ...
Страница 583: ...Software 583 Memo ...
Страница 690: ...Operation and Maintenance 690 Memo ...
Страница 719: ...XXIX Memo ...