Hardware
328
Features of Internal RAID Controller
This section describes the features of Internal RAID Controller.
Rebuild
If a HDD is defected, the rebuild feature can recover the data in the defected HDD. This
feature can be performed to the redundant virtual disks such as RAID1,RAID5.
Manual Rebuild
The manual rebuild can be performed by using WebBIOS or Universal RAID Utility, the
management utility of Internal RAID Controller. Select a HDD and start the rebuild manually.
Auto Rebuild
Internal RAID Controller can automatically start the rebuild without use of any utility such as
Universal RAID Utility.
The auto rebuild includes two types as follows:
●
Standby rebuild
Automatic rebuild by using hot-spares. In the configuration including hot-spares, the
rebuild is performed automatically if a HDD assigned to a virtual disk is defected.
●
Hot-swap rebuild
Automatic rebuild by hot-swapping defected HDD.
IMPORTANT:
When executing Rebuild, note that
* Use the new HDD which has the same capacity, the same
performance(rpm), and the same specification as the old one
which is replaced because of a failure/error.
* While Rebuild, the system perforamance might be down.
* While Rebuild, don’t shut down or reboot the system.
If the power was OFF accidentally while Rebuild, Power ON the
system as soon as possible. Then Rebuild will be restarted
automatically.
* More than 90 seconds interval is required between the timing of
removing the old HDD and the timing of inserting the new one.
* If Hot-swap rebuild does not work well,try Manual rebuild.
Содержание Express 5800
Страница 73: ...73 Memo ...
Страница 279: ...Hardware 279 3 BIOS Menu screen is displayed ...
Страница 336: ...Hardware 336 Display Screen for WebBIOS Physical Drives Property Screen for Universal RAIDUtility Physical Devices ...
Страница 339: ...Hardware 339 3 BIOS will start Select Save Exit then press Enter ...
Страница 365: ...Hardware 365 6 Select Home at the lower left of the screen and press Enter to go back to WebBIOS Home Menu ...
Страница 444: ...444 Part Number Part number FRU File ID FRU file ID Asset Tag Asset management tag ...
Страница 526: ...526 Then input User Name for Authentication and select Keyboard interactive Then input Password ...
Страница 573: ...573 Memo ...
Страница 583: ...Software 583 Memo ...
Страница 690: ...Operation and Maintenance 690 Memo ...
Страница 719: ...XXIX Memo ...