Hardware
371
Slot numbers and their indications on utility software
Hard disk drive
Slot number of server
Indication on Web BIOS
Indication on URU
Slot#0
( ):1:0
Slot 1
Slot#1
( ):1:1
Slot 2
Slot#2
( ):1:2
Slot 3
Slot#3
( ):1:4
Slot 5
Slot#4
( ):1:5
Slot 6
Slot#5
( ):1:6
Slot 7
Slot#6
( ):1:8
Slot 9
Slot#7
( ):1:9
Slot 10
Slot#8
( ):1:10
Slot 11
Slot#9
( ):1:12
Slot 13
Slot#10
( ):1:13
Slot 14
Slot#11
( ):1:14
Slot 15
Setting of Priority
WebBIOS displays and sets Rebuild Priority and Patrol Read Priority, Consistency Check
Priority of RAID Controller by percentage. But, Universal RAID Utility uses three levels as
High/Middle/Low for them.
Setting value of WebBIOS and the display level of Universal RAID Utility
Item
Setting level of WebBIOS
Setting level of URU
80
~
100
High
31-79 Middle
Rebuild Priority
Rebuild Rate (WebBIOS)
0-30 Low
80
~
100
High
31-79 Middle
Patrol Read Priority
Patrol Read Rate (WebBIOS)
0-30 Low
80
~
100
High
31-79 Middle
Consistency Check Priority
CC Rate (WebBIOS)
0-30 Low
Содержание Express 5800
Страница 73: ...73 Memo ...
Страница 279: ...Hardware 279 3 BIOS Menu screen is displayed ...
Страница 336: ...Hardware 336 Display Screen for WebBIOS Physical Drives Property Screen for Universal RAIDUtility Physical Devices ...
Страница 339: ...Hardware 339 3 BIOS will start Select Save Exit then press Enter ...
Страница 365: ...Hardware 365 6 Select Home at the lower left of the screen and press Enter to go back to WebBIOS Home Menu ...
Страница 444: ...444 Part Number Part number FRU File ID FRU file ID Asset Tag Asset management tag ...
Страница 526: ...526 Then input User Name for Authentication and select Keyboard interactive Then input Password ...
Страница 573: ...573 Memo ...
Страница 583: ...Software 583 Memo ...
Страница 690: ...Operation and Maintenance 690 Memo ...
Страница 719: ...XXIX Memo ...