Operation and Maintenance
624
Specifying Failure of Power Cable
Since a failure of power cable is not detected by BID (Build
In Diagnostic), judge if the cable must
be replaced or not for a failure.
When the AC power is properly supplied to the power supply unit, the status LED of the unit
blinks in green. When the DC power is properly supplied, the status LED of the unit lights in
green.
If the status LED of the unit remains unlit after checking the following points, replace the power
cable as the cable may be failed.
1. Is the power supply unit properly connected to the server and the releasing lever locked?
2. Is the power cable properly connected to the AC inlet of the power supply unit?
3. Is the switch of outlet box (PDU) on?
4. Is the power cable properly connected to the outlet box (PDU) or to the outlet?
5. Is the power properly supplied to the outlet box (PDU)?
Check the following points to find the potential cause of the problem if possible.
For the combination of the power supply unit functioning properly and the power cable:
a. Connect the properly functioning power cable to the power supply unit that the suspected
cable is connected.
b. Connect the suspected power cable to the power supply unit that is properly functioning.
Example) In the case of “a.”
Example) In the case of “b.”
Power cable
Status LED of power unit 4
does not light.
If status LED of power unit 4 blinks and lights, the
unit is functioning properly and the power cable is
suspected as a failure.
Power cable
Status LED of power unit 4
does not light.
If status LED of power unit 3 does not blink
or light, the power cable is suspected as a
failure.
Содержание Express 5800
Страница 73: ...73 Memo ...
Страница 279: ...Hardware 279 3 BIOS Menu screen is displayed ...
Страница 336: ...Hardware 336 Display Screen for WebBIOS Physical Drives Property Screen for Universal RAIDUtility Physical Devices ...
Страница 339: ...Hardware 339 3 BIOS will start Select Save Exit then press Enter ...
Страница 365: ...Hardware 365 6 Select Home at the lower left of the screen and press Enter to go back to WebBIOS Home Menu ...
Страница 444: ...444 Part Number Part number FRU File ID FRU file ID Asset Tag Asset management tag ...
Страница 526: ...526 Then input User Name for Authentication and select Keyboard interactive Then input Password ...
Страница 573: ...573 Memo ...
Страница 583: ...Software 583 Memo ...
Страница 690: ...Operation and Maintenance 690 Memo ...
Страница 719: ...XXIX Memo ...