Installing C.P. Components
8:22
CP 1 – Cathodic Protection Tester Course Manual
©
NACE International, 2000
07/01/04
Surface Groundbed Configurations
General
Surface groundbeds are those where the anodes are installed either
vertically or horizontally at a depth of typically five to fifteen feet below
the surface. The anodes are usually connected to a header cable, which in
turn is connected to the positive terminal of the rectifier.
Surface groundbeds are of either point or distributed configuration. Either
vertical or horizontal anodes may be used in each. Each configuration is
discussed below.
Vertical Anode Installation
Auger to the depth indicated on the plans. This is important as the design is
based on the resistivity of the soil and the depth of the water table.
If you are installing bare anodes, place and thoroughly tamp the designed
amount of coke breeze in the bottom of the hole. Lower in the anode using
support ropes--do not lower the anode by the lead wire. Center the anode in
the hole and thoroughly tamp layers of coke breeze backfill to the specified
level above the top of the anode. Tamp native soil above the coke breeze to
the level of the bottom of the header cable trench. Be very careful not to
damage the anode lead wire insulation.
A similar procedure is used for prepackaged anodes. Although there is coke
breeze within the canister, designs often call for coke breeze to be installed
under, around, and over the canister.
A typical vertical anode installation is shown below in Figure 8.19.
Содержание CP 1
Страница 1: ...CP 1 Cathodic Protection Tester Course Manual February 2005 NACE International 2000 ...
Страница 265: ......
Страница 266: ......
Страница 267: ......
Страница 268: ......
Страница 301: ...RP0169 2002 32 NACE International ISBN 1 57590 035 1 ...
Страница 535: ...TM0101 2001 24 NACE International ISBN 1 57590 137 4 ...