Underground Corrosion Control
3:36
CP 1 – Cathodic Protection Tester Course Manual
©
NACE International, 2000
02/01/05
-0.31 V
-0.29 V
14 mA
Conventional Current
Corrosion Current
Same Meter
-0.31 V
-0.29 V
14 mA
Conventional Current
Corrosion Current
Same Meter
Part B
1. Place magnesium anode in tray and connect to the copper sheet through a
10,000-ohm resistor.
2.
Measure corrosion current (I
corr
).
3.
Determine the cathodic protection current (I
c,p
) by calculating it from the voltage drop across the
variable resistance.
4.
Measure polarized potentials of steel and copper.
10 mV
-0.31 V
-0.29 V
5 mA
10,000 O
1,000 O
100 O
10 O
Same Meter
10 mV
10 mV
-0.31 V
-0.29 V
5 mA
10,000 O
1,000 O
100 O
10 O
Same Meter
Part C
1. Repeat Part B using 100-ohm and 10-ohm resistors.