Stray Current Interference
6:10
CP 1 – Cathodic Protection Tester Course Manual
©
NACE International, 2000
02/01/05
Results
Experimental Step
Cathodically Protected
Structure Potentials (mV)
Foreign Structure
Potential (mV)
A B C D E F
Step 2
Step 5
Step 7 & 8
CONCLUSIONS
1.
Stray current pickup and a negative potential shift on the foreign
structure occurs at position F.
2.
Stray current discharge and a positive potential shift on the foreign
structure occurs at position D.
3.
The potentials on the cathodically protected structure are altered by the
presence of the foreign structure because the current distribution has
been disturbed.