Field Measurements
5:28
CP 1 – Cathodic Protection Tester Course Manual
©
NACE International, 2000
02/01/05
Measuring Electrolyte Resistivity
Wenner Four-Pin Method
Most soil resistivity measurements are made by the four-pin Wenner
method. This method is used to determine the resistivity of soil within an
area. The Wenner procedure involves driving four metallic pins into the
earth, in a straight line, equally spaced. The pin spacing is equal to the
depth of investigation of the average soil resistivity, as shown in Figure
5.12. The average soil resistivity is a function of the voltage drop between
the center pair of pins with current flowing between the two outside pins.
After resistance is measured at a given spacing, then the spacing can be
changed and resistance measured at the new spacing.
a
ρ = 2 π
a R
a
a
P1
P2
C1
C2
Resistivity Test
Instrument
Figure 5.12 Four-Pin (Wenner) Method of Measuring Soil Resistivity
It is important that the pins are placed in a straight line and that they are
equally spaced. Nearby metallic underground structures will create a false
reading since they become part of the measured circuit. Consequently, the
nearest pin should be at least 1.5 times the pin spacing from any
underground metallic structures. Where this is not possible, the pins should
be set at right angles to the underground structure.
The resistance, “R,” at each pin spacing “a”, is the resistance from ground
level to a depth equal to the spacing of the pins.
Содержание CP 1
Страница 1: ...CP 1 Cathodic Protection Tester Course Manual February 2005 NACE International 2000 ...
Страница 265: ......
Страница 266: ......
Страница 267: ......
Страница 268: ......
Страница 301: ...RP0169 2002 32 NACE International ISBN 1 57590 035 1 ...
Страница 535: ...TM0101 2001 24 NACE International ISBN 1 57590 137 4 ...