Interface Cables
Chapter Two: Installation
24
Interface Cables
As of January 1, 1996, most products shipped to the European Community must comply with the
EMC Directive 89/336/EEC, which covers radio frequency emissions and immunity tests. In
addition, as of January 1, 1997, some products shipped to the European Community must also
comply with the Product Safety Directive 92/59/EEC and Low Voltage Directive 73/23/EEC,
which cover general safety practices for design and workmanship. MKS products that meet
these requirements are identified by application of the CE Mark.
Note
Only 1179 Series units with a Type “D” connector or digital
communications connector can be CE marked. The Edge Card connector
is not CE compliant.
To ensure compliance with EMC Directive 89/336/EEC, an overall metal braided shielded cable,
properly grounded at both ends, is required during use. No additional installation requirements
are necessary to ensure compliance with Directives 92/59/EEC and 73/23/EEC.
Note
1. An overall metal braided, shielded cable, properly grounded at both
ends, is required during use to meet CE specifications.
2. To order an overall metal braided shielded cable, add an “S” after the
cable type designation. For example, to order a cable to connect an
1179 unit equipped with a 15-pin Type “D” connector to a 146 unit,
use part number CB47-1-XX, where XX designates the cable length;
for a braided, shielded cable use part number CB147S-1-XX.
MKS offers a variety of interface cables, listed in Table 5.
MKS Cables
To Connect To A . . .
15-pin Type “D”
9-pin Type “D”
20-pin Edge Card
PR4000, 146, 186, 167, 647
CB147-1-xx
CB147-12-xx
CB147-7-xx
246, 247
CB259-5-xx
CB147-12-xx
CB259-10-xx
where xx indicates the cable length
Table 5: MKS Cables
Содержание Mass-Flo 1179A
Страница 3: ...116527 P1 Rev E 3 99 MKS Type 1179A and 2179A Mass Flo Controller and Type 179A Mass Flo Meter...
Страница 8: ...Table of Contents vi...
Страница 10: ...List of Figures and Tables viii...
Страница 54: ...How To Use the Optional Input MFC only Chapter Four Operation 44 This page intentionally left blank...
Страница 66: ...How To Adjust the Valve Preload MFC only Chapter Seven Troubleshooting 56 This page intentionally left blank...
Страница 70: ...Physical Specifications Appendix A Product Specifications 60 This page intentionally left blank...
Страница 74: ...Model Code Appendix B Model Code Explanation 64 This page intentionally left blank...
Страница 84: ...How To Determine the Valve Configuration Appendix D MFC Sizing Guidelines 74 This page intentionally left blank...