Appendix C: Gas Correction Factors
Common Gases
67
GAS
SYMBOL
SPECIFIC HEAT, Cp
cal/goC
DENSITY
g/l @ 0oC
CONVERSION
FACTOR
Hydrogen Chloride
Hydrogen Fluoride
Isobutylene
Krypton
Methane
HCl
HF
C
4
H
8
Kr
CH
4
0.1912
0.3479
0.3701
0.0593
0.5328
1.627
0.893
2.503
3.739
0.715
1.00
1.00
0.29
1.543
0.72
Methyl Fluoride
Molybdenum Hexafluoride
Neon
Nitric Oxide
Nitrogen
CH
3
F
MoF
6
Ne
NO
N
2
0.3221
0.1373
0.246
0.2328
0.2485
1.518
9.366
0.900
1.339
1.250
0.56
0.21
1.46
0.99
1.00
Nitrogen Dioxide
Nitrogen Trifluoride
Nitrous Oxide
Octafluorocyclobutane
(Freon - C318)
Oxygen
NO
2
NF
3
N
2
O
C
4
F
8
O
2
0.1933
0.1797
0.2088
0.185
0.2193
2.052
3.168
1.964
8.937
1.427
.- - -2
0.48
0.71
0.17
0.993
Pentane
Perfluoropropane
Phosgene
Phosphine
Propane
C
5
H
12
C
3
F
8
COCl
2
PH
3
C
3
H
8
0.398
0.194
0.1394
0.2374
0.3885
3.219
8.388
4.418
1.517
1.967
0.21
0.17
0.44
0.76
0.36
Propylene
Silane
Silicon Tetrachloride
Silicon Tetrafluoride
Sulfur Dioxide
C
3
H
6
SiH
4
SiCl
4
SiF
4
SO
2
0.3541
0.3189
0.1270
0.1691
0.1488
1.877
1.433
7.580
4.643
2.858
0.41
0.60
0.28
0.35
0.69
(Table continued on next page)
Содержание Mass-Flo 1179A
Страница 3: ...116527 P1 Rev E 3 99 MKS Type 1179A and 2179A Mass Flo Controller and Type 179A Mass Flo Meter...
Страница 8: ...Table of Contents vi...
Страница 10: ...List of Figures and Tables viii...
Страница 54: ...How To Use the Optional Input MFC only Chapter Four Operation 44 This page intentionally left blank...
Страница 66: ...How To Adjust the Valve Preload MFC only Chapter Seven Troubleshooting 56 This page intentionally left blank...
Страница 70: ...Physical Specifications Appendix A Product Specifications 60 This page intentionally left blank...
Страница 74: ...Model Code Appendix B Model Code Explanation 64 This page intentionally left blank...
Страница 84: ...How To Determine the Valve Configuration Appendix D MFC Sizing Guidelines 74 This page intentionally left blank...